Customised Industrial High Temperature High Efficient Dust Collector for Fly Ash is mainly used in raw material conveying system, to separate and eliminate the dust contained in gas. The dust from raw materials would be collected in silo. Therefore, it prevents air pollution and pollution dispersion. Based on installation type, fly ash dust collector is classified into integral silo pressure-relief (roof) pulse dust collector and split silo pressure-relief (roof) pulse dust collector.
Technical Parameters of Customised Industrial High Temperature High Efficient Dust Collector for Fly Ash
|
|||||||||
Item
|
DMC24
|
DMC36
|
DMC48
|
DMC60
|
DMC72
|
DMC84
|
DMC96
|
DMC108
|
DMC120
|
Air volume passing(m3/h)
|
870-3240
|
1300-4880
|
1730-6500
|
2170-8130
|
2600-9750
|
3040-11400
|
3470-13000
|
3900-14630
|
4340-16270
|
Filtration rate(M/min)
|
0.8~3
|
0.8~3
|
0.8~3
|
0.8~3
|
0.8~3
|
0.8~3
|
0.8~3
|
0.8~3
|
0.8~3
|
Filtering area(m2)
|
18
|
27.1
|
36.1
|
45.2
|
54.2
|
63.3
|
72.3
|
81.3
|
90.4
|
Filter bag spec.(mm)
|
Ø120X2000
|
Ø120X2000
|
Ø120X2000
|
Ø120X2000
|
Ø120X2000
|
Ø120X2000
|
Ø120X2000
|
Ø120X2000
|
Ø120X2000
|
No. of filter bag
|
24
|
36
|
48
|
60
|
72
|
84
|
96
|
108
|
120
|
Equipment resistance(Pa)
|
980-1200
|
980-1200
|
980-1200
|
980-1200
|
980-1200
|
980-1200
|
980-1200
|
980-1200
|
980-1200
|
Collection efficiency(%)
|
99~99.9
|
99~99.9
|
99~99.9
|
99~99.9
|
99~99.9
|
99~99.9
|
99~99.9
|
99~99.9
|
99~99.9
|
Inlet dust concentration(g/m3)
|
<15
|
<15
|
<15
|
<15
|
<15
|
<15
|
<15
|
<15
|
<15
|
No. of pulse valve(S)
|
4
|
6
|
8
|
10
|
12
|
14
|
16
|
18
|
20
|
pulse cycle(S)
|
0.1~0.2
|
0.1~0.2
|
0.1~0.2
|
0.1~0.2
|
0.1~0.2
|
0.1~0.2
|
0.1~0.2
|
0.1~0.2
|
0.1~0.2
|
Injection pressure(MPa)
|
0.5~0.7
|
0.5~0.7
|
0.5~0.7
|
0.5~0.7
|
0.5~0.7
|
0.5~0.7
|
0.5~0.7
|
0.5~0.7
|
0.5~0.7
|
Compressed air consumption((m3/min)
|
0.084~0.168
|
0.162~0.252
|
0.168~0.336
|
0.21~0.42
|
0.252~0.504
|
0.294~0.588
|
0.336~0.672
|
0.378~0.756
|
0.42~0.84
|
Working temperature(ºC)
|
<120
|
<120
|
<120
|
<120
|
<120
|
<120
|
<120
|